Set

Function

This API is used to set Thermal > Measurement Rule page

Request Message

Parameter Description

See Thermal > Measurement Rule > Response Message >Parameter Description > Table 2 Get Parameter description.

Sample:

POST /API/Thermal/Setup/MeasurementRules/Set HTTP/1.1
{ "version": "1.0", "data": { "channel_info": {"CH2": { "status": "Online", "switch": true, "colorbar_switch": false, "display_temp_on_optical": false, "display_temp_on_stream": true, "display_max_temp": true, "display_min_temp": false, "display_average_temp": false, "display_pos": "Near Target", "spot_measurement": false, "data_refresh_rate": "3", "temp_unit": "Degree Celsius", "emissivity": 0.96, "distance_unit": "Meter", "target_distance": 1, "reflective_temp": 20, "chn_index": "CH2", "page": "chn_measurement" }}, "page_type": "ChannelConfig" } }

Response Message

none

Sample:

HTTP/1.1 200 OK Content-Type: application/json
{ "result": "success", "data": {} }

Error Code

See Response message body and general error_code for more information.